'''Imaging particle analysis''' is a technique for making particle measurements using [[digital imaging]], one of the techniques defined by the broader term [[particle size analysis]]. The measurements that can be made include [[particle size]], particle shape (morphology or [[shape analysis (digital geometry)|shape analysis]] and [[grayscale]] or [[RGB color model#Numeric representations|color]], as well as distributions (graphs) of [[Population (statistics)|statistical population]] measurements.
Line 6 ⟶ 5:
Imaging particle analysis uses the techniques common to [[image analysis]] or [[image processing]] for the analysis of particles. Particles are defined here per [[particle size analysis]] as particulate solids, and thereby not including atomic or sub-atomic particles. Furthermore, this article is limited to [[real image]]s (optically formed), as opposed to "synthetic" (computed) images ([[computed tomography]], [[confocal microscopy]], SIM and other [[super resolution microscopy]] techniques, etc.).
Given the above, the primary method for imaging particle analysis is using optical microscopy. While [[optical microscope]]s have been around and used for particle analysis since the
Beginning in the late
Finally, beginning roughly in the late
As faster computing resources became available at lowered costs, the task of making measurements from microscope images of particles could now be performed automatically by machine without human intervention, making it possible to measure significantly larger numbers of particles in much less time.
Line 16 ⟶ 15:
The basic process by which imaging particle analysis is carried out is as follows:
# A digital camera captures an image of the [[field of view]] in the optical system.
# A gray scale [[Thresholding (image processing)|thresholding]] process is used to perform [[Image segmentation#Thresholding|image segmentation]], segregating out the particles from the background, creating a [[binary image]] of each particle.<ref name=Gonzalez>{{cite book|last=Gonzalez|first=Rafael C.|title=Digital Image Processing|year=2002|publisher=Pearson Education|isbn=
# [[Digital image processing]] techniques are used to perform [[image analysis]] operations, resulting in morphological and grey-scale measurements to be stored for each particle.<ref name="CarterYan2005">{{cite journal|last1=Carter|first1=R M|last2=Yan|first2=Y|title=Measurement of particle shape using digital imaging techniques|journal=Journal of Physics: Conference Series|volume=15|issue=1|year=2005|pages=177–182|issn=1742-6588|doi=10.1088/1742-6596/15/1/030|bibcode = 2005JPhCS..15..177C |doi-access=free}}</ref>
# The measurements saved for each particle are then used to generate image population statistics,<ref>{{cite web|last=Pouli|first=T.|title=Image Statistics and their Applications in Computer Graphics (2010)|url=http://www.cs.bris.ac.uk/~reinhard/papers/eg2010_tania.pdf|archive-url=https://wayback.archive-it.org/all/20110401055809/http://www.cs.bris.ac.uk/~reinhard/papers/eg2010_tania.pdf|url-status=dead|archive-date=1 April 2011|publisher=Eurographics, State of the Art|accessdate=2 January 2014|author2=Cunningham, D
Imaging particle analyzers can be subdivided into two distinct types, static and dynamic, based upon the image acquisition methods. While the basic principles are the same, the methods of image acquisition are different in nature, and each has advantages and disadvantages.
Line 25 ⟶ 24:
Static image acquisition is the most common form. Almost all microscopes can be easily adapted to accept a digital camera via a [[C mount]] adaptor. This type of set-up is often referred to as a [[digital microscope]], although many systems using that name are used only for displaying an image on a [[Video monitor#video display|monitor]].
The sample is prepared on a microscope slide which is placed on the [[Optical microscope#Stage|microscope stage]]. Once the sample has been focused on, then an image can be acquired and displayed on the monitor. If it is a [[digital camera]] or a [[frame grabber]] is present, the image can now be saved in digital format, and image processing algorithms can be used to isolate particles in the field of view and measure them.<ref>{{cite book|last=Russ|first=J.C.|title=Computer-Assisted Microscopy: The Measurement and Analysis of Images|year=1990|publisher=Springer US|isbn=978-1-4612-7868-9}}</ref><ref>{{cite book|
In static image acquisition only one field of view image is captured at a time. If the user wishes to image other portions of the same sample on the slide, they can use the X-Y positioning hardware (typically composed of two [[linear stage]]s on the microscope to move to a different area of the slide. Care must be taken to insure that two images do not overlap so as not to count and measure the same particles more than once.
The major drawback to static image acquisition is that it is time consuming, both in sample preparation (getting the sample onto the slide with proper dilution if necessary), and in multiple movements of the stage in order to be able to acquire a statistically significant number of particles to count/measure. Computer-controlled X-Y positioning stages are sometimes used in these systems to speed the process up and to reduce the amount of operator intervention, but it is still a time consuming process, and the motorized stages can be expensive due to the level of precision required when working at high magnification.<ref name=Brown>{{cite web|last=Brown|first=L.|title=Dynamic Versus Static Image Acquisition in Particle Imaging|url=http://www.particleimaging.com/dynamic-versus-static-image-acquisition-in-particle-imaging/|work=www.particleimaging.com|accessdate=2 January 2014|archive-url=https://web.archive.org/web/20140103060115/http://www.particleimaging.com/dynamic-versus-static-image-acquisition-in-particle-imaging/|archive-date=3 January 2014|url-status=dead}}</ref>
The major advantages to static particle imaging systems are the use of standard microscope systems and simplicity of [[depth of field]] considerations. Since these systems can be made from any standard optical microscope, they may be a lower cost approach for people who already have microscopes. More important, though, is that microscope-based systems have less depth of field issues generally versus dynamic imaging systems. This is because the sample is placed on a microscope slide, and then usually covered with a [[cover slip]], thus limiting the plane containing the particles relative to the [[optical axis]]. This means that more particles will be in acceptable focus at high magnifications.<ref name=Brown />
=== Dynamic imaging particle analysis ===
[[File:Basic flow through diag on white.png|thumb|Diagram showing flow-through architecture for dynamic imaging particle
[[File:Flow cell Cross Section.png|thumb
The major drawback to dynamic image acquisition is that the flow cell depth must be limited as described above. This means that, in general, particles larger in size than the flow cell depth can not be allowed in the sample being processed, because they will probably clog the system. So the sample will typically have to be filtered to remove particles larger than the flow cell depth prior to being evaluated. If it is desired to look at a very wide range of particle size, this may mean that the sample would have to be fractionated into smaller size range components, and run with different magnification/flow cell combinations.<ref name=Brown />
The major advantage to dynamic image acquisition is that it enables acquiring and measuring particles at significantly higher
Dynamic imaging particle analysis is used in aquatic microorganism research to analyze phytoplankton, zooplankton, and other aquatic microorganisms ranging from 2 um to 5 mm in size. Dynamic imaging particle analysis is also biopharmaceutical research to characterize and analyze particles ranging from 300 nm to 5mm in size.
===Micro-flow imaging===
''Micro-flow imaging (MFI)'' is a particle analysis technique that uses flow [[microscopy]] to quantify particles contained in a solution based on size. This technique is used in the [[biopharmaceutical]] industry to characterize subvisible particles from approximately 1 μm to >50 μm.<ref>{{cite journal | pmc = 2895433 | pmid=20517661 | doi=10.1208/s12248-010-9205-1 | volume=12 | issue=3 | title=Micro-flow imaging: flow microscopy applied to sub-visible particulate analysis in protein formulations | year=2010 | journal=AAPS J | pages=455–64 | last1 = Sharma | first1 = DK | last2 = King | first2 = D | last3 = Oma | first3 = P | last4 = Merchant | first4 = C}}</ref>