In [[control theory]], an '''open-loop controller''', also called a '''non-feedback controller''', is a [[control loop]] part of a [[control system]] in which the control action
There are many open-[[Control loop|loop]] controls, such as on/off switching of valves, machinery, lights, motors or heaters, where the control result is known to be approximately sufficient under normal conditions without the need for feedback. The advantage of using open-loop control in these cases is the reduction in component count and complexity. However, an open-loop system cannot correct any errors that it makes or correct for outside disturbances
== Open-loop and closed-loop
{{excerpt|Control loop#Open-loop and closed-loop}}
== Applications ==
[[File:Electric Clothes dryer.jpg|thumb|Electric clothes dryer, which is open-loop controlled by running the dryer for a set time, regardless of clothes dryness.]]
An open-loop controller is often used in simple processes because of its simplicity and low cost, especially in systems where feedback is not critical. A typical example would be an older model domestic [[clothes dryer]], for which the length of time is entirely dependent on the judgement of the human operator, with no automatic feedback of the dryness of the clothes.
For example, an [[irrigation sprinkler]] system, programmed to turn on at set times could be an example of an open-loop system if it does not measure [[soil]] [[moisture]] as a form of feedback. Even if rain is pouring down on the lawn, the sprinkler system would activate on schedule, wasting water.
Line 32 ⟶ 24:
Thus there are many open-loop controls, such as switching valves, lights, motors or heaters on and off, where the result is known to be approximately sufficient without the need for feedback.
==
A feed back control system, such as a [[PID controller]], can be improved by combining the [[feedback]] (or [[closed-loop
For example, in most motion control systems, in order to accelerate a mechanical load under control, more force is required from the actuator. If a velocity loop PID controller is being used to control the speed of the load and command the force being applied by the actuator, then it is beneficial to take the desired instantaneous acceleration, scale that value appropriately and add it to the output of the PID velocity loop controller. This means that whenever the load is being accelerated or decelerated, a proportional amount of force is commanded from the actuator regardless of the feedback value. The PID loop in this situation uses the feedback information to change the combined output to reduce the remaining difference between the process setpoint and the feedback value. Working together, the combined open-loop feed-forward controller and closed-loop PID controller can provide a more responsive control system in some situations.
Line 44 ⟶ 36:
* [[PID controller]]
* [[Process control]]
* [[Open-loop transfer function]]
==References==
{{Reflist}}
==Further reading==
* Kuo, Benjamin C. (1991). ''Automatic Control Systems'' (6th ed.). New Jersey: Prentice Hall. {{ISBN|0-13-051046-7}}.
* Ziny Flikop (2004). "Bounded-Input Bounded-Predefined-Control Bounded-Output" (http://arXiv.org/pdf/cs/0411015)
Line 52 ⟶ 47:
{{Electric machines}}
{{Authority control}}
[[Category:Classical control theory]]
|