Content deleted Content added
No edit summary |
m Reverted edits by Harshbohot_7310 (talk): addition of unnecessary/inappropriate external links (HG) (3.4.12) |
||
(46 intermediate revisions by 28 users not shown) | |||
Line 1:
{{Short description|Button or lever to activate fire alarms}}
{{other uses|Fire alarm (disambiguation)}}
{{refimprove|date=October 2008}}
[[File:Simplex pull station.jpg|thumb|200px|right|[[SimplexGrinnell|Simplex]] single action "T-bar" pull station]]
[[File:
[[File:Proprietary-type fire alarm manual call point-activated.JPG|thumb|right|200px|An activated manual call point in Japan. Telephone jacks are visible beneath the open cover.]]
[[File:Feuermelder 01 KMJ.jpg|thumb|right|200px|German manual call point with paint from NOTIFIER (Honeywell)]]
<!-- Deleted image removed: [[File:Wireless Fire Alarm Call Point UK.jpg|thumb|right|Wireless Manual Call Point for temporary environments. (WES+)]] -->
'''Manual fire alarm activation''' is
When a fire pull station or call point is activated, codes usually require evacuation begin immediately. There are certain exemptions like system maintenance and security [[Lockdown|lockdowns]], where manual activation outside the control panel may be overridden.<ref>{{Cite web |last=tmagna |date=2022-03-30 |title=Which fire alarm signal should be used? |url=https://www.csemag.com/articles/which-fire-alarm-signal-should-be-used/ |access-date=2023-02-05 |website=Consulting - Specifying Engineer |language=en-US}}</ref> Security alarms, emergency door releases, industrial fire suppression systems, and hazardous material leak alarms are all examples of specialty systems which are sometimes activated with similar manual initiating devices to a fire alarm. They may be linked to fire alarm systems to varying degrees.
== Fire alarm pull station ==
A '''fire alarm pull station''' is an [[active fire protection]] device, usually wall-mounted, that, when activated, initiates an alarm on a [[fire alarm]] system. This is the most common design in North America. In its simplest form, the user activates the alarm by pulling the handle down, which completes a circuit and locks the handle in the activated position, sending an alarm to the [[fire alarm control panel]]. After operation, most fire alarm pull stations must be restored to the ready position using a special tool or key for the panel to be reset. Primitive manual stations, requiring only a single action or hand motion to activate, can be subject to unwanted activation by jarring or accidental contact. Early strategies to cope with this problem included requiring the operator to break a pane of glass to release an internal spring-operated mechanism. Manual pull stations that require two hand motions, such as lift up and pull down, or push in and pull down, have since replaced the break-glass and single-action models in many modern installations.
=== Coded pull stations ===
In the past, pull stations controlled the entire system. These coded pull stations were much bigger than modern pulls and had a code wheel in them. They had a gear mechanism that was wound up when the station was pulled, and (unlike modern pull stations) the handle did not stay down. The gears would turn a small wheel with a specific number of teeth, which determined the coding. The teeth would push up on a contact, which would open and close a circuit, pulsing the code to the bells or horns. This code was used by building security to determine where the alarm was originating from. For example, consider a pull station in the fourth-floor elevator lobby of an office building with a code of 5-3-1. When the station was pulled, the security officers in the building would look up 5-3-1 in a master list of codes. After finding the ___location of the pull, they
check to see if there is a real fire. If there was, they would evacuate the building and call the fire department. [[Image:Holtzercabotpull.JPG|thumb|200px|right|Antique [[Holtzer-Cabot]] coded pull station]]
System tests could be conducted in one of two ways: In a coded pull station, there is either a test hole on the front (usually activated with an [[Allen wrench]]) or a test switch on the inside. Turning the switch one way causes the [[Fire alarm notification appliance | notification appliances]] to sound continuous (or in the case of single-stroke bells, ding once). Turning it the other way and then activating the pull allows a silent test to be done in which the station's mechanical parts are checked to ensure proper function. Once pulled, the station would do at least four rounds of code before resetting itself. Coded pulls were typically used in new fire alarm systems until roughly the 1950s, and then occasionally into the 1970s. Until the early 1990s, some panels were made with an extra zone to accommodate any existing coded pull stations. Nowadays, coded pull stations are rarely seen in working fire alarm systems.
=== Modern pull stations ===
Many modern fire alarm pull stations are single
[[File:Activated Fire-Lite BG-12 pull station at MBTA Chinatown station.jpg|thumb|200px|Activated Notifier NBG-12 pull station underneath a Stopper cover]]
Resetting a fire alarm pull station after it has been operated normally requires building personnel or emergency responders to open the station using a key, which often is either a [[hex key]] or a more traditional key. Opening the station causes the handle to go back to its original position, allowing the alarm to be reset from the [[fire alarm control panel]] after the station has been closed.
In some places, particularly at college dormitories and schools, students deliberately set off fire alarms as a [[practical joke|prank]] or
== Manual call points ==
In Europe, Australia, New Zealand
Manual call points are used to initiate an alarm signal and operate using a simple button press or when glass is broken revealing a button. They can form part of a manual alarm system or an automatic alarm system. There will be an indicator on the monitoring unit for visual indication to locate the call point easily, and there should be a visual identifier of the unit which triggered the alarm, typically a mechanical flag that operates on a latch and must be manually reset, e.g. by a key.
[[File:BNG-1R.jpg|alt= A Notifier pull station at Oklahoma State University. The orange sticker on it warns would-be pranksters of the consequences of false alarms.|thumb|273x273px|A Notifier pull station at [[Oklahoma State University–Stillwater|Oklahoma State University.]] The orange sticker on it warns would-be pranksters of the consequences for [[False alarm|false alarms.]]]]
Previously, the old British standard did not allow hinged covers and plastic resettable elements. Plastic elements must have the same printing as the [[EN 54]] glass.
In the US and Canada, alarm initiating devices with button-like designs are sometimes used in high-hazard occupancies. The [[NFPA 72]] standard uses the term Alarm Box, which could encompass a number of initiation mechanisms.<ref>{{Cite web |title=NFPA 72 National Fire Alarm and Signaling Code® § 3.3.12 Alarm Box. Vian NFPA LiNK® |url=https://link.nfpa.org/free-access/publications/72/2022 |access-date=2023-02-05 |website=link.nfpa.org |language=en}}</ref> A few manual call points have been approved to [[UL (safety organization)|UL]]/UL Canada standards.<ref>{{Cite web |title=Product Datasheets |url=https://maplearmor.com/en/resources/fire-alarm-devices-technical-datasheets/ |access-date=2023-02-05 |website=Maple Armor |language=en-CA}}</ref><ref>{{Cite web |title=DI-M9204 Digital Manual Call Point |url=https://gst.com.cn/en/data/products/Manuals/DI-M9204%20Digital%20Manual%20Call%20Point%20Manual%20Issue%201.02.pdf |website=Gulf Security Technology Co., Ltd.}}</ref> At the time of this writing, the pull station is still the most prominent design in this part of the world.
A report by the UK-based [[Building Research Establishment]] (BRE) stated "there is a commonly held view that equipment designed to meet the European EN54 Fire detection and fire alarm systems standard cannot be used within an installation designed to the US National Fire Alarm Code, NFPA 72." In actuality, "there appears to be no requirement in NFPA 72 that precludes the use of manual call points..."<ref>{{Cite web |date=2010-06-04 |title=BRE Global report finds compatibility between NFPA 72 code, EN54 standards |url=https://www.fmlink.com/articles/bre-global-report-finds-compatibility-between-nfpa-72-code-en54-standards/ |access-date=2023-02-05 |website=FMLink |language=en-US}}</ref>
[[File:Legrand1.jpg|alt= An older [[Legrand (company)|Legrand]] Manual call point. This call point uses a lever-shaped key to reset.|thumb|273x273px|An older [[Legrand (company)|Legrand]] Manual call point. This call point uses a lever-shaped key to reset.]]
Line 47 ⟶ 50:
Due to their use for life inherent purposes, radio receivers used in such systems should be of Category 1<ref>[http://www.etsi.org/technologies-clusters/technologies/radio/short-range-devices Short Range Devices]</ref> standard.
Systems for use during construction can be wireless or mechanical. In the United Kingdom, interconnecting wireless systems are recommended for timber-framed construction.<ref>{{Cite web |last= |first= |date= |title=Structural Timber Association - 16 Steps to Fire Safety |url=http://www.structuraltimber.co.uk/information-centre/information-centre/downloads/health-and-safety/ |url-status=dead |archive-url=https://web.archive.org/web/20140716165530/http://www.structuraltimber.co.uk/information-centre/information-centre/downloads/health-and-safety/ |archive-date=2014-07-16 |accessdate=2015-04-17 |website=Structural Timber Association |publisher=}}</ref>
==European Standard==▼
Fire detection and alarm products placed on the market within the European Union must, following [[Regulation (EU) No 305/2011]], conform to the European harmonized technical standard '''EN 54 Fire Detection and Fire Alarm Systems'''.
[[EN 54]] '''part 11''' is the section of the mandatory standard relating to '''manual call points'''.
[[European Committee for Standardization]] (CEN, French: {{Lang|fr|Comité Européen de Normalisation|italic=no}}) is responsible for the development and maintenance of the standard, as part of its remit for developing harmonized European standards for free movement of goods in the European Union countries.
The
If an EN 54 certificate is over one year old, it has expired and it is not a valid certificate. Manufacturers can not sell or install the device with expired certification in any country of the European Union.<ref>{{cite web |url=http://www.cen.eu/cen/Sectors/TechnicalCommitteesWorkshops/CENTechnicalCommittees/Pages/Standards.aspx?param=6055&title=Fire%20detection%20and%20fire%20alarm%20systems |title=