Content deleted Content added
Afrasiab2020 (talk | contribs) No edit summary |
GreenC bot (talk | contribs) Move 1 url. Wayback Medic 2.5 per WP:URLREQ#nih.gov |
||
(4 intermediate revisions by 4 users not shown) | |||
Line 1:
Biomaterials exhibit various degrees of compatibility with the harsh environment within a living organism. They need to be nonreactive chemically and physically with the body, as well as integrate when deposited into tissue
== Background of Polymer Biomaterials ==
Line 19:
! Applications of Plasma Treatments!! Devices !! Materials !! Purposes
|-
| Biosensor || Sensor Membranes, Diagnostic biosensors || PC, Cellulose,[[Cuprophane]], PP, PS || Immobilization of biomolecules, non-fouling surfaces
|-
| Cardiovascular || Vascular grafts, Catheters || PET,PTFE,PE,SiR || Improved biocompatibility, Wettability tailoring, lubricious coatings, Reduced friction, Antimicrobial coatings
Line 80:
=== Guide Wires ===
Guide wires are an example of an application for biomedical coatings. Guide wires are used in [[percutaneous coronary intervention|coronary angioplasty]] to correct the effects of [[coronary artery disease]], a disease that allows plaque build up on the walls of the arteries. The guide wire is threaded up through the femoral artery to the obstruction. The guide wire guides the balloon catheter to the obstruction where the catheter is inflated to press the plaque against the arterial walls.<ref name=angioplasty>{{cite web |url=https://www.
==== Hydrophilic Coatings ====
Hydrophilic coatings can reduce friction in the arteries by up to 83% when compared to bare wires due to their high surface energy.<ref name=friction>{{cite journal |pmid=8485751 |year=1993 |last1=Schröder |first1=J |title=The mechanical properties of guidewires. Part III: Sliding friction |volume=16 |issue=2 |pages=93–7 |journal=CardioVascular and Interventional Radiology |doi=10.1007/BF02602986|s2cid=7941986 }}</ref> When the hydrophilic coatings come into contact with bodily fluids they form a waxy surface texture that allows the wire to slide easily through the arteries. Guide wires with hydrophilic coatings have increased trackability and are not very thrombogenic; however the low coefficient of friction increases the risk of the wire slipping and perforating the artery.<ref name=techniques>{{cite journal |first1=Andrejs |last1=Erglis |first2=Inga |last2=Narbute |first3=Dace |last3=Sondore |first4=Alona |last4=Grave |first5=Sanda |last5=Jegere |title=Tools & Techniques: coronary guidewires |journal=EuroIntervention |url=http://www.pcronline.com/eurointervention/tools-and-techniques/coronary-guidewires/download_pdf.php |pmid=20542813 |year=2010 |volume=6 |issue=1 |pages=168–9 |doi=10.4244/eijv6i1a24 |url-access=subscription }}</ref>
==== Hydrophobic Coatings ====
|