Biomaterial surface modifications: Difference between revisions

Content deleted Content added
CmdrObot (talk | contribs)
sp: an noncorrosive→a noncorrosive
GreenC bot (talk | contribs)
 
(36 intermediate revisions by 27 users not shown)
Line 1:
Biomaterials exhibit various degrees of compatibility with the harsh environment within a living organism. They need to un-reactivebe nonreactive chemically and physically with the body, as well as integrate when withdeposited into tissue.<ref name=biomaterial>{{cite journal |doi=10.1007/BF00680113 |pmid=8052058 |title=Biomaterials for abdominal wall hernia surgery and principles of their applications |year=1994 |last1=Amid |first1=P. K. |last2=Shulman |first2=A. G. |last3=Lichtenstein |first3=I. L. |last4=Hakakha |first4=M. |journal=Langenbecks Archiv für Chirurgie |volume=379 |issue=3 |pages=168–71|s2cid=22297566 }}</ref> The extent of compatibility varies based on the application and material required. Often modifications to the surface of a biomaterial system are required to maximize performance. The surface can be modified in many ways, including plasma modification and applying coatings to the substrate. Surface modifications can be used to affect [[surface energy]], [[adhesion]], [[biocompatibility]], chemical inertness, lubricity, [[Sterilization (microbiology)|sterility]], [[asepsis]], [[Thrombosis|thrombogenicity]], susceptibility to [[corrosion]], degradation, and [[hydrophile|hydrophilicity]].
 
== Background of Polymer Biomaterials ==
Line 5:
=== Polytetrafluoroethylene (Teflon) ===
 
[[polytetrafluoroethylene|Teflon]] is a hydrophobic polymer composed of a carbon chain saturated with fluorine atoms. The fluorine-carbon bond is largely ionic, producing a strong dipole. The dipole prevents Teflon from being susceptible to [[Van der Waals forcesforce]]s, so other materials will not stick to the surface.<ref name=teflon>{{cite web |url=http://www.sigmaaldrich.com/technical-documents/articles/material-matters/fluorinated-hyperbranched.html |title= Fluorinated Hyperbranched Polymers |last1= Mueller |first1= Anja |year= 2006 |work= Sigma Aldrich |accessdate=19 May 2013}}</ref> Teflon is commonly used to reduce friction in biomaterial applications such as in arterial grafts, catheters, and guide wire coatings.
 
=== Polyetheretherketone (PEEK) ===
 
[[File:Polyetherketon.svg|thumb|Polyetheretherketone (PEEK) is a thermoplastic, semicrystalline polymer. The backbone consists of ether, ketone, and benzene groups]]
[[PEEK]] is a semicrystalline polymer composed of benzene, ketone, and ether groups. PEEK is known for having good physical properties including high wear resistance and low moisture absorption <ref name=teflonteflon2>{{cite web |url= http://www.boedeker.com/peek_p.htm |title= PEEK (PolyEtherEtherKetone) Specifications |year= 2013 |work= Boedeker Plastics |accessdate=20 May 2013}}</ref> and has been used for biomedical implants due to its relative inertness inside of the human body.
 
== Plasma modification of biomaterials ==
 
Plasma modification is one way to alter the surface of biomaterials to enhance their properties. During plasma modification techniques, the surface is subjected to high levels of excited gases that alter the surface of the material. Plasma's are generally generated with a [[Radio frequency|radio frequency (RF)]] field. Additional methods include applying a large (~1KV) DC voltage across electrodes engulfed in a gas. The plasma is then used to expose the biomaterial surface, which can break or form chemical bonds. This is the result of physical collisions or chemical reactions of the excited gas molecules with the surface. This changes the surface chemistry and therefore surface energy of the material which affects the adhesion, biocompatibility, chemical inertness, lubricity, and sterilization of the material. The table below shows several biomaterial applications of plasma treatments.<ref>{{cite webjournal |last=Loh |first=Ih-Houng |workjournal=AST Technical Journal |title=Plasma Surface Modification In Biomedical Applications |year=1999 |volume=10 |issue=1 |pages=24–30 |pmid=10344871 |url=http://www.astp.com/PDFs/PSBiomed.pdf |url-status=dead |archiveurl=https://web.archive.org/web/20080514091530/http://www.astp.com/PDFs/PSBiomed.pdf |archivedate=2008-05-14 }}</ref>
{| class="wikitable"
|-
! Applications of Plasma Treatments!! Devices !! Materials !! Purposes
|-
| Biosensor || Sensor Membranes, Diagnostic biosensors || PC, Cellulose,[[Cuprophane]], PP, PS || Immobilization of biomolecules, non-fouling surfaces
|-
| Cardiovascular || Vascular grafts, Catheters || PET,PTFE,PE,SiR || Improved biocompatibility, Wettability tailoring, lubricious coatings, Reduced friction, Antimicrobial coatings
Line 25:
| Dental || Dental Implants || Ti alloys || Enhanced Cell growth
|-
| Orthopedic || Joints,Ligaments || [[Ultra-high-molecular-weight polyethylene|UHMWPE]],PET || Enhance bone adhesion, Enhanced tissue in-growth
|-
| Others || General uses || Example || Sterilization, Surface cleaning, Etching, Adhesion promotion, Lubricity tailoring
Line 34:
The [[surface energy]] is equal to the sum of disrupted molecular bonds that occur at the interface between two different phases. Surface energy can be estimated by [[contact angle]] measurements using a version of the [[Young–Laplace equation]]:
 
<math> \gamma_{SV} - \gamma_{SL}= \gamma_{LV} cos\theta </math> <ref name=CA>{{cite book |doi=10.1021/ba-1964-0043.ch001 |chapter=Relation of the Equilibrium Contact Angle to Liquid and Solid Constitution |title=Contact Angle, Wettability, and Adhesion |series=Advances in Chemistry |year=1964 |last1=Zisman |first1=W. A. |isbn=978-0-8412-0044-09 |volume=43 |pages=1–51 |editor1-first=Frederick M. |editor1-last=Fowkes}}</ref>
 
Where <math>\gamma_{SV}</math> is the surface tension at the interface of solid and vapor, <math>\gamma_{SL}</math> is the surface tension at the interface of solid and liquid, and <math>\gamma_{LV}</math> is the surface tension at the interface of liquid and vapor. Plasma modification techniques alter the surface of the material, and subsequently the surface energy. Changes in surface energy then alter the surface properties of the material.
Line 41:
 
[[Surface modification]] techniques have been extensively researched for the application of adsorbing biological molecules. Surface functionalization can be performed by exposing surfaces to RF plasma. Many gases can be excited and used to functionalize surfaces for a wide variety of applications. Common techniques include using air plasma, oxygen plasma, and ammonia plasma as well as other exotic gases. Each gas can have varying effects on a substrate. These effects decay with time as reactions with molecules in air and contamination occur.
[[File:Argon plasma used for polymer surface functionalization prior to bonding.Argon plasma used for polymer surface functionalization prior to bonding.png|125 × 240 pixels.0px|thumb|right|Argon plasma used for polymer surface functionalization prior to bonding.]]
 
==== Plasma Treatment to Reduce Thrombogenesis ====
 
 
Ammonia plasma treatment can be used to attach amine functional groups. These functional groups lock on to anticoagulants like Heparin decreasing thrombogenicity.<ref>{{cite journal |doi=10.1002/jbm.820270614 |title=Immobilization of high-affinity heparin oligosaccharides to radiofrequency plasma-modified polyethylene |year=1993 |last1=Yuan |first1=Shengmei |last2=Szakalas-Gratzl |first2=Gyongyi |last3=Ziats |first3=Nicholas P. |last4=Jacobsen |first4=Donald W. |last5=Kottke-Marchant |first5=Kandice |last6=Marchant |first6=Roger E. |journal=Journal of Biomedical Materials Research |volume=27 |issue=6 |pages=811–9 |pmid=8408111}}</ref>
Line 50 ⟶ 49:
==== Covalent Immobilization by Gas Plasma RF Glow Discharge ====
 
[[Polysaccharide]]s have been used as [[thin film]] coatings for biomaterial surfaces. Polysaccharides are extremely hydrophilic and will have small [[contact angle]]s. They can be used for a wide range of applications due to their wide range of compositions. They can be used to reduce the [[adsorption]] of proteins to biomaterial surfaces. Additionally, they can be used as receptor sites, targeting specific biomolecules. This can be used to activate specific biological responses.
 
Covalent attachment to a substrate is necessary to immobilize polysaccharides, otherwise they will rapidly desorb in a biological environment. This can be a challenge due to the fact that the majority of biomaterials do not possess the surface properties to covalently attach polysaccharides. This can be achieved by the introduction of [[amine|amine groups]] by RF glow discharge plasma. Gases used to form amine groups, including ammonia or n-heptylamine vapor, can be used to deposit a thin film coating containing surface amines. Polysaccharides must also be activated by oxidation of anhydroglucopyranoside subunits. This can be completed with sodium metaperiodate (NaIO<sub>4</sub>). This reaction converts anhydroglucopyranoside subunits to cyclic hemiacetal structures, which can be reacted with amine groups to form a Schiff base linkage (a carbon-nitrogen double bond). These linkages are unstable and will easily [[dissociation (chemistry)|dissociate]]. Sodium cyanoborohydride (NaBH<sub>3</sub>CN) can be used as a stabilizer by reducing the linkages back to an amine.<ref name=immobilization>{{cite journal |doi=10.1002/(SICI)1096-9918(200001)29:1<46::AID-SIA692>3.0.CO;2-6 |title=Biomedical coatings by the covalent immobilization of polysaccharides onto gas-plasma-activated polymer surfaces |year=2000 |last1=Dai |first1=Liming |last2=Stjohn |first2=Heather A. W. |last3=Bi |first3=Jingjing |last4=Zientek |first4=Paul |last5=Chatelier |first5=Ronald C. |last6=Griesser |first6=Hans J. |journal=Surface and Interface Analysis |volume=29 |pages=46–55}}</ref>
Line 56 ⟶ 55:
=== Surface Cleaning ===
 
There are many examples of contamination of biomaterials that are specific to the preparation or manufacturing process. Additionally, nearly all surfaces are prone to contamination of organic impurities in the air. Contamination layers are usually limited to a monolayer or less of atoms and are thus only detectable by surface analysis techniques, such as XPS. It is unknown whether this sort of contamination is harmful, yet it is still regarded as contamination and will most certainly have an impact onaffect surface properties.
 
Glow discharge plasma treatment is a technique that is used for cleaning contamination from biomaterial surfaces. Plasma treatment has been used for various biological evaluation studies to increase the surface energy of biomaterial surfaces, as well as cleaning.<ref name=RFGD>{{cite journal |doi=10.1002/jbm.820290411|title=Effect of parallel surface microgrooves and surface energy on cell growth |year=1995 |last1=den Braber |first1=E.T. |last2=de Ruijter |first2=J.E. |last3=Smits |first3=H.T.J |last4=Ginsel |first4=L.A. |last5=von Recum |first5=A.F. |last6=Jamsen |first6=J.A. |journal=Journal of Biomedical Materials Research |volume=29 |pages=511–518 |pmid=7622536 |issue=1|hdl=2066/21896 |hdl-access=free }}</ref> Plasma treatment has also been proposed for [[sterilization (microbiology)|sterilization]] of biomaterials for potential implants.<ref name=glow>{{cite journal |doi=10.1002/(SICI)1097-4636(199704)35:1<49::AID-JBM6>3.0.CO;2-M |title=Glow discharge plasma treatment for surface cleaning and modification of metallic biomaterials |year=1997 |last1=Aronsson |first1=B.-O. |last2=Lausmaa |first2=J. |last3=Kasemo |first3=B. |journal=Journal of Biomedical Materials Research |volume=35 |issue=1 |pages=49–73 |pmid=9104698 |issue=1}}</ref>
[[File:Glow Plasma Discharge Schematic Polymer Chemistry.png|framed|center|Schematic of cleaning of a polymer surface using glow plasma discharge. Note the removal of adsorbed molecules and presence of dangling bonds.]]
 
Line 67 ⟶ 66:
=== Adhesion of Coatings ===
 
In general, the lower the surface tension of a liquid coating, the easier it will be to form a satisfactory wet film from it. The difference between the surface tension of a coating and the surface energy of a solid substrate to which a coating is applied affects how the liquid coating flows out over the substrate. It also affects the strength of the adhesive bond between the substrate and the dry film. If for instance, the surface tension of the coating is higher than the surface tension of the substrate, then the coating will not spread out and form a film. As the surface tension of the substrate is increased, it will reach a point to where the coating will successfully wet the substrate but have poor adhesion. Continuous increase in the coating surface tension will result in better wetting in film formation and better dry film adhesion.<ref name=SurfaceTension>{{cite web |url= http://www.pra-world.com/technical_services/laboratory/testing/surface-tension |title= Surface Tension, Surface Energy, Contact Angle and Adhesion |year= 2013 |work= Paint Research Association |accessdate= 22 May 2013 |url-status= dead |archiveurl= https://web.archive.org/web/20130109105050/http://www.pra-world.com/technical_services/laboratory/testing/surface-tension |archivedate= 9 January 2013 }}</ref>
 
More specifically whether a liquid coating will spread across a solid substrate can be determined from the surface energies of the involved materials by using the following equation:
Line 77 ⟶ 76:
==== Corrosion Protection ====
 
Organic coatings are a common way to protect a metallic substrate from [[corrosion]]. Up until ~1950 it was thought that coatings act as a physical barrier which disallows moisture and oxygen to contact the metallic substrate and form a corrosion cell. This cannot be the case because the [[Permeation|permeability]] of paint films is very high. It has since been discovered that corrosion protection of steel depends greatly upon the adhesion of a noncorrosive coating when in the presence of water. With low adhesion, osmotic cells form underneath the coating with high enough pressures to form blisters, which expose more unprotected steel. Additional non-osmotic mechanisms have also been proposed. In either case, sufficient adhesion to resist displacement forces is required for corrosion protection.<ref name=CoatingsBook>{{cite book| author author1= Z.W. Wicks; |author2=Frank N. Jones; |author3=S. Peter Pappas; |author4=Douglas A. Wicks | title = Organic Coatings Science and Technology | edition = 2nd expanded | ___location = New Jersey | publisher = [[John Wiley & Sons, Inc.]] }}{{page needed|date=June 2013}}</ref>
 
=== Guide Wires ===
 
Guide wires are an example of an application for biomedical coatings. Guide wires are used in [[percutaneous coronary intervention|coronary angioplasty]] to correct the effects of [[coronary artery disease]], a disease that allows plaque build up on the walls of the arteries. The guide wire is threaded up through the femoral artery to the obstruction. The guide wire guides the balloon catheter to the obstruction where the catheter is inflated to press the plaque against the arterial walls.<ref name=angioplasty>{{cite web |url=httphttps://www.nlm.nihmedlineplus.gov/medlineplus/ency/anatomyvideos/000096.htm |title= Percutaneous transluminal coronary angioplasty (PTCA) |last1= Gandelman |first1= Glenn |date= March 22, 2013 |work= Medline Plus |accessdateaccess-date=19 May 2013}}</ref> Guide wires are commonly made from stainless steel or [[Nickel Titanium|Nitinol]] and require polymer coatings as a surface modification to reduce friction in the arteries. The coating of the guide wire can affect the trackability, or the ability of the wire to move through the artery without kinking, the tactile feel, or the ability of the doctor to feel the guide wire's movements, and the thrombogenicity of the wire.
 
==== Hydrophilic Coatings ====
 
Hydrophilic coatings can reduce friction in the arteries by up to 83% when compared to bare wires due to their high surface energy.<ref name=friction>{{cite journal |pmid=8485751 |year=1993 |last1=Schröder |first1=J |title=The mechanical properties of guidewires. Part III: Sliding friction |volume=16 |issue=2 |pages=93–7 |journal=CardiovascularCardioVascular and interventionalInterventional radiologyRadiology |doi=10.1007/BF02602986|s2cid=7941986 }}</ref> When the hydrophilic coatings come into contact with bodily fluids they form a waxy surface texture that allows the wire to slide easily through the arteries. Guide wires with hydrophilic coatings have increased trackability and are not very thrombogenic; however the low coefficient of friction increases the risk of the wire slipping and perforating the artery.<ref name=techniques>{{cite journal |first1=Andrejs |last1=Erglis |first2=Inga |last2=Narbute |first3=Dace |last3=Sondore |first4=Alona |last4=Grave |first5=Sanda |last5=Jegere |title=Tools & Techniques: coronary guidewires |journal=EuroIntervention |url=http://www.pcronline.com/eurointervention/tools-and-techniques/coronary-guidewires/download_pdf.php |pmid=20542813 |year=2010 |volume=6 |issue=1 |pages=168–9 |doi=10.4244/eijv6i1a24 |doi_brokendateurl-access=June 16,subscription 2013}}</ref>
 
==== Hydrophobic Coatings ====
 
Teflon and [[Silicone]] are commonly used [[hydrophobe|hydrophobic]] coatings for coronary guide wires. Hydrophobic coatings have a lower surface energy and reduce friction in the arteries by up to 48%.<ref name=friction/> Hydrophobic coatings do not need to be in contact with fluids to form a slippery texture. Hydrophobic coatings maintain tactile sensation in the artery, allowinggiving doctors full control of the wire at all times and reducing the risk of perforation; though, the coatings are more thrombogenic than hydrophilic coatings.<ref name=techniques/> The thrombogenicity is due to the proteins in the blood adapting to the hydrophobic environment when they adhere to the coating. This causes an irreversible change for the protein, and the protein remains stuck to the coating allowing for a blood clot to form.<ref name=thrombo>{{cite journal |first=Denis |last=Labarre |title=Improving blood compatibility of polymeric surfaces |journal=Trends in Biomaterials and& Artificial Organs |year=2001 |volume=15 |issue=1 |pages=1–3 |url=http://www.biomaterials.org.in/ojs/index.php/tibao/article/view/5 |access-date=2013-06-16 |archive-url=https://web.archive.org/web/20160304064255/http://www.biomaterials.org.in/ojs/index.php/tibao/article/view/5 |archive-date=2016-03-04 |url-status=dead }}</ref>
 
==== Magnetic Resonance Compatible Guide Wires ====
 
Using an [[Magnetic Resonance Imaging|MRI]] to image the guide wire during use would have an advantage over using x-rays because the surrounding tissue can be examined while the guide wire is advanced. Because most guide wires' core materials are stainless steel they are not capable of being imaged with an MRI. Nitinol wires are not magnetic and could potentially be imaged, but in practice the conductive nitinol heats up under the magnetic radiation which would damage surrounding tissues. An alternative that is being examined is to replace contemporary guide wires with PEEK cores, coated with iron particle embedded synthetic polymers.<ref name=MRI>{{cite journal |doi=10.1002/jmri.20486 |title=A polymer-based MR-compatible guidewire: A study to explore new prospects for interventional peripheral magnetic resonance angiography (ipMRA) |year=2006 |last1=Mekle |first1=Ralf |last2=Hofmann |first2=Eugen |last3=Scheffler |first3=Klaus |last4=Bilecen |first4=Deniz |journal=Journal of Magnetic Resonance Imaging |volume=23 |issue=2 |pages=145–55 |pmid=16374877|doi-access=free }}</ref>
{| class="wikitable"
|-
Line 104 ⟶ 103:
| PEEK || 42.1 <ref name=PEEKse>{{cite web |url=http://www.surface-tension.de/solid-surface-energy.htm|title= Solid surface energy data (SFE) for common polymers |date= November 20, 2007 |accessdate=2 June 2013}}</ref>
|-
| Stainless Steel || 44.5 <ref name=SSse>{{cite web |url=http://www.kruss.de/en/theory/substance-properties/solids.html|title= Selected literature values for surface free energy of solids |accessdate=5 June 2013|archive-url=https://web.archive.org/web/20130529084018/http://www.kruss.de/en/theory/substance-properties/solids.html|archive-date=29 May 2013|url-status=dead}}</ref>
|-
| Nitinol || 49 <ref name=nitinolse>{{cite journal |doi=10.1016/j.biomaterials.2006.09.040 |title=The influence of surface energy on competitive protein adsorption on oxidized NiTi surfaces |year=2007 |last1=Michiardi |first1=Alexandra |last2=Aparicio |first2=Conrado |last3=Ratner |first3=Buddy D. |last4=Planell |first4=Josep A. |last5=Gil |first5=Javier |journal=Biomaterials |volume=28 |issue=4 |pages=586–94 |pmid=17046057}}</ref>
Line 113 ⟶ 112:
{{Reflist}}
 
[[Category:BiologyBiomaterials]]
{{improve categories|date=June 2013}}
 
[[Category:Biology]]