In [[control theory]], an '''open-loop controller''', also called a '''non-feedback controller''', is a [[control loop]] part of a [[control system]] in which the control action
There are
== Open-loop and closed-loop
{{excerpt|Control loop#Open-loop and closed-loop}}
== Applications ==
[[File:Electric Clothes dryer.jpg|thumb|Electric clothes dryer, which is open
An open-loop controller is often used in simple processes because of its simplicity and low cost, especially in systems where feedback is not critical. A typical example would be
For example, an [[irrigation sprinkler]] system, programmed to turn on at set times could be an example of an open-loop system if it does not measure [[soil]] [[moisture]] as a form of feedback.
Another example is a [[
However, open-loop control is very useful and economic for well-defined systems where the relationship between input and the resultant state can be reliably modeled by a mathematical formula. For example, determining the [[voltage]] to be fed to an [[electric motor]] that drives a constant load, in order to achieve a desired [[speed]] would be a good application. But if the load were not predictable and became excessive, the motor's speed might vary as a function of the load not just the voltage, and an open-loop controller would be insufficient to ensure repeatable control of the velocity.
Line 29 ⟶ 22:
An example of this is a conveyor system that is required to travel at a constant speed. For a constant voltage, the conveyor will move at a different speed depending on the load on the motor (represented here by the weight of objects on the conveyor). In order for the conveyor to run at a constant speed, the voltage of the motor must be adjusted depending on the load. In this case, a closed-loop control system would be necessary.
Thus there are
==
A feed back control system, such as a [[PID controller]], can be improved by combining the [[feedback]] (or [[closed-loop
For example, in most motion control systems, in order to accelerate a mechanical load under control, more force is required from the actuator. If a velocity loop PID controller is being used to control the speed of the load and command the force being applied by the actuator, then it is beneficial to take the desired instantaneous acceleration, scale that value appropriately and add it to the output of the PID velocity loop controller. This means that whenever the load is being accelerated or decelerated, a proportional amount of force is commanded from the actuator regardless of the feedback value. The PID loop in this situation uses the feedback information to change the combined output to reduce the remaining difference between the process setpoint and the feedback value. Working together, the combined open-loop feed-forward controller and closed-loop PID controller can provide a more responsive control system in some situations.
==See also==
Line 43 ⟶ 36:
* [[PID controller]]
* [[Process control]]
* [[Open-loop transfer function]]
==References==
{{Reflist}}
==Further reading==
* Kuo, Benjamin C. (1991). ''Automatic Control Systems'' (6th ed.). New Jersey: Prentice Hall. {{ISBN|0-13-051046-7}}.
* Ziny Flikop (2004). "Bounded-Input Bounded-Predefined-Control Bounded-Output" (http://arXiv.org/pdf/cs/0411015)
* Basso, Christophe (2012). "Designing Control Loops for Linear and Switching Power Supplies: A Tutorial Guide". Artech House, {{ISBN|978-1608075577}}
{{Electric machines}}
[[Category:Control theory]]▼
{{Authority control}}
|