A simplifying assumption in this ___domain is that all heat transfer mechanisms are linear, implying that radiation and convection are linearised for each problem.
Several publications can be found that describe how to generate lumped-element models of buildings. In most cases, the building is considered a single thermal zone and in this case, turning multi-layered walls into lumped elements can be one of the most complicated tasks in the creation of the model. The dominant-layer method is one simple and reasonably accurate method.<ref>Ramallo-González, A.P., Eames, M.E. & Coley, D.A., 2013. Lumped Parameter Models for Building Thermal Modelling: An Analytic approach to simplifying complex multi-layered constructions. Energy and Buildings, 60, pp.174-184.</ref> In this method, one of the layers is selected as the dominant layer in the whole construction, this layer is chosen considering the most relevant frequencies of the problem.
Lumped-element models of buildings have also been used to evaluate the efficiency of domestic energy systems, by running many simulations under different future weather scenarios.<ref>Cooper, S.J.G., Hammond, G.P., McManus, M.C., Ramallo-Gonzlez, A. & Rogers, J.G., 2014. Effect of operating conditions on performance of domestic heating systems with heat pumps and fuel cell micro-cogeneration. Energy and Buildings, 70, pp.52-60.</ref>
|