Key Code Qualifier: Difference between revisions

Content deleted Content added
Dancrumb (talk | contribs)
Neilm (talk | contribs)
No edit summary
Line 91:
|-
|1||81||00||Internal logic failure
|-
|rowspan="38" vertical-align="top"|Not Ready||2 ||04 ||00 ||Not Ready - start motor failed
|-
Ready |2 ||04 ||01 ||Not Ready - becoming ready
|-
|2 ||04 ||02 ||Not Ready - need initialise command (start unit)
|-
|2 ||04 ||03 ||Not Ready - manual intervention required
|-
|2 ||04 ||04 ||Not Ready - format in progress
|-
|2 ||04 ||09 ||Not Ready - self-test in progress
|-
|2 ||31 ||00 ||Not Ready - medium format corrupted
|-
|2 ||31 ||01 ||Not Ready - format command failed
|-
|2 ||35 ||02 ||Not Ready - enclosure services unavailable
|-
|2 ||40 ||80 ||Diagnostic Failure - bring-up fail or degraded mode
|-
|2 ||40 ||81 ||Diagnostic Failure - Hard Disk Controller
|-
|2 ||40 ||85 ||Diagnostic Failure - RAM microcode not loaded
|-
|2 ||40 ||90 ||Diagnostic Failure - RRO Calibration
|-
|2 ||40 ||91 ||Diagnostic Failure - Channel Calibration
|-
|2 ||40 ||92 ||Diagnostic Failure - Head Load
|-
|2 ||40 ||93 ||Diagnostic Failure - Write AE
|-
|2 ||40 ||94 ||Diagnostic Failure - 12V over current
|-
|2 ||40 ||95 ||Diagnostic Failure - Other spindle failure
|-
|2 ||40 ||B0 ||Diagnostic Failure - self-reset
|-
|2 ||4C ||00 ||Diagnostic Failure - config not loaded
|}
 
<pre>
Not 2 04 00 Not Ready - start motor failed
Ready 2 04 01 Not Ready - becoming ready
2 04 02 Not Ready - need initialise command (start unit)
2 04 03 Not Ready - manual intervention required
2 04 04 Not Ready - format in progress
2 04 09 Not Ready - self-test in progress
2 31 00 Not Ready - medium format corrupted
2 31 01 Not Ready - format command failed
2 35 02 Not Ready - enclosure services unavailable
2 40 80 Diagnostic Failure - bring-up fail or degraded mode
2 40 81 Diagnostic Failure - Hard Disk Controller
2 40 85 Diagnostic Failure - RAM microcode not loaded
2 40 90 Diagnostic Failure - RRO Calibration
2 40 91 Diagnostic Failure - Channel Calibration
2 40 92 Diagnostic Failure - Head Load
2 40 93 Diagnostic Failure - Write AE
2 40 94 Diagnostic Failure - 12V over current
2 40 95 Diagnostic Failure - Other spindle failure
2 40 B0 Diagnostic Failure - self-reset
2 4C 00 Diagnostic Failure - config not loaded
Medium 3 03 00 Medium Error - write fault
Error 3 0C FF Medium Error - write recovery time limit exceeded