== Test Performance ==
The '''single-breath diffusing capacity test''' is the most common way to determine <math>D_L</math>.<ref name="multiple" /> The test is performed by having the subject blow out all of the air that he/she can, leaving only the [[Lung volumes|residual lung volume]] of gas. The person then inhales a test gas mixture rapidly and completely, reaching the [[Lung volumes|total lung capacity]] as nearly as possible. This test gas mixture contains a small amount of carbon monoxide (usually 0.3%) and a ''tracer gas'' that is freely distributed throughout the alveolar space but which doesn't cross the alveolar-capillary membrane. [[Helium]] and [[methane]] are two such gasses. The test gas is held in the lung for about 10
The anatomy of the airways brings with it complications, since the inspired air must pass through the mouth, trachea, bronchi and bronchioles before it gets to the alveoli where gas exchange will occur; on exhalation, alveolar gas must return along the same path, and so the exhaled sample will be purely alveolar only after a 500 to 1,000
{{NumBlk|::|<math>\dot{V}_{CO} =\frac {\Delta{[CO]} * V_A} {\Delta{t}} </math> . | {{EquationRef|4}} }}
::::The pulmonary function equipment monitors the change in the concentration of CO that occurred during the breath hold, <math>\Delta{[CO]}</math>, and also records the time <math>\Delta{t}</math>.
|