IRIG timecode: Difference between revisions

Content deleted Content added
Adding local short description: "Standard formats for transferring time information", overriding Wikidata description "set of standard formats for transferring timing information"
Timecodes: Not sure we need a word problem.
Line 36:
| 1 Hz || 1 s || 60 || 1 minute || {{frac|60}} Hz
|}
 
 
'''IRIG Code B Calculation''':<br>
 
Bit rate = 100 Hz = 100 × (1 / second) = 100 / second = 100 / 1000 ms = 1 / 10ms<br>
 
Bit time = 1 / (Bit rate) = 1 / (1 / 10 ms) = 10 ms<br>
 
There are 100 Bits per frame.<br>
 
Frame time = (Bits per frame) × (Bit time) = 100 × 10 ms = 1000 ms = 1 second<br>
 
Frame rate = 1 / (Frame time) = 1 / 1 second = 1 Hz<br>
<br>
 
The bits are modulated on a carrier. A three-digit suffix specifies the type and frequency of the carrier, and which optional information is included:
Line 74 ⟶ 60:
* Year number (00–99; century is not coded)
* User-defined "control functions (CF)" occupying bits not defined by IRIG
* "Straight binary seconds (SBS)", a 17-bit binary counter that counts from 0 to 86399.<ol start=0 type=1>
<ol start=0 type=1>
<li>BCD, CF, SBS</li>
<li>BCD, CF</li>