Reactances of synchronous machines: Difference between revisions

Content deleted Content added
top: Expanding article
Line 1:
{{in use}}
The '''reactances of synchronous machines''' is a set of characteristic constants used in the theory of [[synchronous machine]]s.{{sfn|Park|Robertson|1928|p=514}} Technically, these constants specified int units of the [[electrical reactance]], although they are typically expressed in the [[per-unit system]] and thus [[dimensionless]].
 
Das{{sfn|Das|2017|pp=180-182}} identifies the following reactances:
* leakage reactance <math>X_l</math>;
* subtransient reactance <math>X''_d</math> with the quadrature-axis counterpart;
* transient reactance <math>X'_d</math>;
* synchronous reactance <math>X_d</math>;
* quadrature axis reactances <math>X_q</math>, <math>X'_q</math>, <math>X''_q</math>, counterparts to <math>X_d</math>, <math>X'_d</math>, <math>X''_d</math>;
* negative sequence reactance <math>X_2</math>;
* zero sequence reactance <math>X_0</math>;
* Potier reactance <math>X_P</math>.
 
== References ==