IRIG timecode: Difference between revisions

Content deleted Content added
m disambig link
SmackBot (talk | contribs)
m Standard headings &/or gen fixes. using AWB
Line 13:
:0) (DCLS) Direct Current Level Shift (width coded)
:1) Sine wave carrier (amplitude modulated),
:2) [[Manchester_codeManchester code|Manchester]] modulated
 
:Carrier Resolution:
Line 45:
For example, one of the most common formats, IRIG B122:
IRIG B122 transmits one hundred pulses per second on an amplitude modulated 1 kHz sine wave carrier, encoding information in BCD. This means that 100 bits of information are transmitted every second. The time frame for the IRIG B standard is 1 second, meaning that one data frame of time information is transmitted every second. This data frame contains information about year (0-99), the day of the year (1-366), hours, minutes, and seconds. Information as to which century it is, is not transmitted. [[Leap second]] announcements are not provided. Although information is transmitted only once per second, a device can sychronize its time very accurately with the transmitting device by using a [[phase locked loop]]. Typical commercial devices will synchronize to within 1 microsecond using IRIG B timecodes.
==ReferenceReferences==
*[https://wsmrc2vger.wsmr.army.mil/rcc/manuals/200-04/TT-45.pdf IRIG standard 200-04 (PDF)]
[[Category:Synchronization]]
 
==External links==
* [http://www.meinberg.de/english/info/irig.htm IRIG information] IRIG information page with diagrams.
 
[[Category:Synchronization]]
[[de: IRIG Timecode]]
 