=== Taper ===
A taper is a transmission line with a gradual change in cross-section. It can be considered the limiting case of the stepped impedance structure with an infinite number of steps.<ref>Zhurbenko, p. 310</ref> Tapers are a simple way of joining two transmission lines of different characteristic impedances. Using tapers greatly reduces the mismatch effects that a direct join would cause. If the change in cross-section is not too great, no other matching circuitry may be needed.<ref>Garg ''et al.'', pp. 180–181</ref> Tapers can provide [[Planar transmission line#Transitions|transitions]] between lines in different media, especially different forms of planar media.<ref>{{multiref|Garg ''et al.'', pp. 404–406, 540|Edwards & Steer, p. 493}}</ref> Tapers commonly change shape linearly, but a variety of other shapes may be used. The shape that produces a taper of the shortest length is known as a Klopfenstein taper and is based on the [[Chebychev filter]] design.<ref>{{multiref|Zhurbenko, p. 311|Misra, p. 276}}</ref>
 
== Circuit blocks ==