If you can address this concern by improving, copyediting, sourcing, renaming, or merging the page, please edit this page and do so. You may remove this message if you improve the article or otherwise object to deletion for any reason. Although not required, you are encouraged to explain why you object to the deletion, either in your edit summary or on the talk page. If this template is removed, do not replace it. This message has remained in place for seven days, so the article may be deleted without further notice. Find sources: "Alarm indication signal" – news · newspapers · books · scholar · JSTOR Timestamp: 20250715181917 18:19, 15 July 2025 (UTC) Administrators: delete |
Another editor has reviewed this page's proposed deletion and endorses both the proposal and the reason given above. If you remove the {{proposed deletion/dated}} tag above, please also remove this {{Proposed deletion endorsed}} tag. |
This article has multiple issues. Please help improve it or discuss these issues on the talk page. (Learn how and when to remove these messages)
|
Alarm indication signal (AIS)[1] (also called all ones because of the data and framing pattern) is a signal transmitted by an intermediate element of a multi-node transport circuit that is part of a concatenated communications system to alert the receiving end of the circuit that a segment of the end-to-end link has failed at a logical or physical level, even if the system it is directly connected to is still working. The AIS replaces the failed data, allowing the higher order system in the concatenation to maintain its transmission framing integrity. Downstream intermediate elements of the transport circuit propagate the AIS onwards to the destination element.
Formats
There are various AIS formats based on the signaling level of the errored circuit. When an element of T1 or (DS1) circuit loses signal (LOS) or framing (OOF), the device replaces the erroneous data bits with a series of ones. This is where the term All Ones originates. At the DS3 signal level, the intermediate element receiving an errored signal replaces the errored channel data with a signal consisting of a valid DS3 frame with the overhead bits (the M-subframe alignment bits, M-frame alignment bits, and P bits) with the payload set to a 1010... sequence, the C bits all set to zero, and the X bits set to one. This way, the integrity of the DS3 frame is maintained even though the underlying data was compromised.
There are a number of types of AIS signals, which signal failure of different logical or physical segments of the system, including:
- Alarm indication signal path (AIS-P)
- Alarm indication signal line (AIS-L)12
These are SONET OC-xx level indications that indicate if the errored element is in a section, segment, line segment, or path segment of the SONET circuit.
Analog systems
Middle 20th century analog carrier systems had Carrier Group Alarms by which the failure of a pilot signal was alerted to telephone exchange equipment, imposing an automated make-busy condition so the trunks carried by the failed system would not be used. The improved AIS originated with the T-carrier system, and became a standard feature of subsequent plesiochronous and synchronous circuit-based communication systems, and is also part of the Asynchronous Transfer Mode standards. As the use of Ethernet for long-distance data links has increased, the need for a similar end-to-end OA&M function has led to the development of a similar Ethernet alarm indication signal (EthAIS).